Applications of Zero Ion G3

1. Bare PCB,PCB module

2. Semiconductor Package (Substrate &Strip &BGA Seal Circuit),Flip Chip,BGA &CSP Package

3. Battery charging board

4. Reliability analysis of boards and parts mounted on defense (land,sea,air,seascape),rail aviation,space,elevators,automobile electric fields,ships,communications,mobile communication repeaters,satellites,etc. Pollution degree measurement

5. Precision parts

6. Hybrid IC

7. Semiconductor materials,etc.


Zero Ion G3 characteristics

1. Dynamic measurement technology applied

l Each used Test Solution (measurement solution) is De-Ionized (purified) in real time and transferred to the measurement chamber to realize precise measurement every time.

l Precision measurement is possible by maximizing Solvency (dissolving ability) and Sensitivity (sensitivity)

l Precise measurement is possible by reducing the Saturation Limit Effect (dissolution penetration suggestion effect)

2. Use room temperature test solution (measurement solution)

l Improving the safety of researchers and equipment and work environment due to evaporation of the measuring solution

l Shorten measurement time,reduce current consumption

3. Application of R.O.S.E (Resistivity of Solvent Extract-Measurement of Solvent Extraction Resistance) measurement method

4. Submerged Spray (spray in chamber containing measurement solution) equipment installed

l Measurement of extraction contamination to minute ionic contaminants

5. Automatic calculation and measurement of NaCL/Square Equivalence according to MIL &IPC regulations

6. Certification from various industry standards

l WS6536

l MIL-P-28809

l ANSI/IP-J-STD-001 TM650

l Navy’s EMPF,etc.

7. Increased the number of measurements due to shortened ion contamination measurement time

l Measured within 3~4 minutes on average from 30 seconds

8. Application of exclusive program for Aqueous Technologies

l User-oriented ease of use

l Real-time measurement process screen display

l Processed as SPC (statistical management) data

l Using Window 7 PC

9. Certified 100% Contamination Value (contamination level) indication

10. ESD stability

l Wrist Strip installed

l Manufactured using ESD safe conductive materials


Zero Ion G3 standard

l Specification:1,353 x 710 x 1,350mm

l Electric Power:230Vac,50/60Hz,1phs

l Max. Testing Size:457 x 457mm

l Control:All-in-One PC

l Interface:18” LCD Monitor

l Dynamic Filtration:Standard

l Test Method:All

l Auto Print:Standard

l SPC Data Storage:Standard

l ESD Counter Top:Standard

l Test Solution:75% IPA,25% DI Water (pure water)

l De-Ionizes System:Standard